Carry-air™ & wall-air™
Filtration Panels |
  |
|
2 WORKER |
5 WORKER |
|
Part No. |
|
Part No. |
|
|
9872 |
Carry-Air w/CO Monitor |
9875 |
Carry-Air w/CO Monitor |
|
9872-40 |
Wall-Air w/CO Monitor |
9875-40 |
Wall-Air w/CO Monitor |
|
9872-WIO |
Carry-Air w/o CO Monitor |
9875-WIO |
Carry-Air w/o CO Monitor |
9872-40
WIO |
Wall-Air w/o CO Monitor |
9875-40
WIO |
Wall-Air w/o CO Monitor |
|
8 WORKER |

9872-40 |
|
Part No. |
|
|
9878 |
Carry-Air w/CO Monitor |
|
9878-40 |
Wall-Air w/CO Monitor |
|
9878-WIO |
Carry-Air w/o CO Monitor |
9878-40
WIO |
Wall-Air w/o CO Monitor |
|
|
|
|
|
Part No. |
Description |
View |
|
9871-02 |
REMOTE CO MONITOR
Attached to any air source or
filter panel, the Remote CO Monitor alerts workers using
supplied air respirators when the level of carbon monoxide has
exceeded 10 ppm. The CO monitor can be operated in AC or
DC mode and uses a single 9-volt alkaline battery. Maximum
regulator inlet pressure is 150 psi. |
 |
|
9871-01 |
REMOTE CO ALARM
The remote CO Alarm System uses a
50' cable to go with workers into the work area and effectively
warn of the presence of carbon monoxide in the air source with a
90 decibel alarm, and in very noisy environments, a flashing
strobe light. The system is housed in a rugged Pelican
carry case or may be wall mounted, and attached to any Allegro
Air Filtration Panel as shown. |
 |
|
9871-03 |
POINT-OF-ATTACHMENT
AIR CONTROL SYSTEM
This Point-of-Attachment (POA)
Air Control System connects to any breathing air source.
It's housed in a Pelican carry case that can be wall-mounted and
includes an adjustable pressure regulator, pressure gauge and a
pressure relief valve. This POA system meets NIOSH
requirements for point of attachment. Maximum regulator
inlet pressure is 150 psi. |
 |
|
9350-03 |
SOURCE PRE-FILTER
Where air quality is especially
low, this free-standing or wall-mounted particulate assembly
helps extend the life of the filter panel's disposable filters
by removing liquids and contaminates down to 5 microns. It
is equipped with an adjustable regulator pressure gauge and
meets the NIOSH requirements for point-of-attachment. |
 |
|
9872-60 |
CO MONITOR CALIBRATION TEST KIT
Used to test the accuracy of the CO Monitor on Allegro's Carry
Air, Wall-Air or Oil-Less Compressor. Kit includes a 17
liter cylinder each of oxygen and CO, a constant flow pressure
regulator with gauge and tubing in a plastic carrying case. |
 |
|
9872-60Q |
CO MONITOR "BUMP TEST" KIT
A compact, lightweight and
convenient way to make a quick check of CO Monitors. It
eliminates the need for weekly or monthly calibrations.
Includes an 11 liter cylinder and a balloon adapter and two
balloons. |
 |